Mains pressure hot water
Here are some brief comments about three different systems...
1) A combi boiler. This heats cold mains water as it passes
through the boiler so you don't need a hot water tank. Not quite what most
people expect from a mains-pressure hot water supply because the flow rate is
very poor, but it IS a mains pressure hot water system.
2) Unvented hot water cylinder. With these, the water in the cylinder is
heated, stored and delivered to your taps as in a conventional hot water
cylinder, but it is fed directly from the mains rather than from a tank in the
loft. Plenty of water flow to the hot taps showers etc, depending entirely on
how fast the mains pipe can deliver water into your house.
If you choose one of these it is crucial that it is installed by competent
person. As the whole cylinder is at mains pressure (or near to, as a pressure
regulator is fitted), they need to understand how to install and commission the
safety devices correctly. There is an extra training course and exam which
plumbers take to qualify them to fit unvented hot water systems. Make sure you
find someone who has this qualification (they will have an identity card to say
so). The Building Regulations state that only suitably qualified people may
install them. Unvented HWCs also need to be serviced annually to check the
safety devices are still working correctly.
The brand-leading unvented HWC is the "MegaFlow" from Heatrae-Sadia.
Have a look at www.heatraesadia.com
3) Thermal stores. These are similar to an ordinary hot water cylinder, but
the water in them never changes. It is heated by a boiler or immersion heaters
and mains cold water is passed through a coil of pipe inside the cylinder so it
can pick up heat from the stored hot water. So you get mains pressure hot water.
Nice idea, but early designs were very prone to lime scaling problems. Scale accumulates on the
inside of the heat transfer coil and restricts both the temperature and flow
rate of the hot water, leading to a £400 descale every two or three years in
certain hard water areas.
Companies like DPS have addressed this problem by using a "plate heat
exchanger" instead of the internal heat transfer coil. plate heat
exchangers are said to be much less susceptible to scaling, and are fitted in
better quality combis for the same reason too. Unfortunately, in my experience
these claims of scale resistance are false. I have a combi and a thermal store
(in flats I rent), both of which have plate heat exchangers which need descaling
regularly. This may be a feature of the water in Reading and Basingstoke.
Heating engineers in other hard water areas (West London for example) report no
scaling problems with plate heat exchangers.
DPS have a website www.heatweb.com
|